Sensors and measurement
Float level switch
A float level switch uses float movement and a defined contact arrangement to indicate a liquid-level condition.
View detailsБеларусь
English technical edition
For a Tolon Level sensor, the machine model and the existing component code come first. Brand names alone do not identify the correct revision, connection layout or operating specification.
Our confirmed contact address is in Ankara, Turkey. A country or city page does not mean that we have an office or technician at that location. Service availability and shipment options are confirmed for each request.
Sensors and measurement
A float level switch uses float movement and a defined contact arrangement to indicate a liquid-level condition.
View detailsSafety switches and interlocks
A pressure-operated switch responds at specified thresholds and may be affected by the condition of its sensing line.
View detailsStart the Tolon catalogue with the machine plate. Compare control electronics, heating, drive and textile transport components against the model, revision and existing part code.
A level sensor may use float, pressure or another method; its sensing principle requires identification.
Compare method, range, output and mounting against the code, including any pressure or sensing line.
Record actual level and controller signal together; a missing indication may involve the sensing connection as well as the sensor.
Sensing method, range, output, mounting position
For Level sensor, begin with the complete machine identification rather than a description remembered from an earlier repair. The model, serial number and existing component code help distinguish revisions that can look alike. Include a photograph of the machine plate and show where the part is fitted. If a label is damaged, say which characters are uncertain. A clear record is more reliable than assuming that every machine from the same brand uses the same component.
A useful record for Level sensor explains what was observed before anything was changed. Note the date, operating conditions, first error and any recent work near the assembly. Keep photographs of the original wiring and mounting position. If a previous replacement did not resolve the symptom, include its code and the result of the follow-up check. This avoids repeating the same assumption and helps separate a component mismatch from an unresolved fault elsewhere in the equipment.
The condition of the parts around Level sensor can matter as much as the component itself. A worn support, loose connection, blocked passage or misaligned assembly may put a new part under the same abnormal conditions. Describe visible wear and the position of any leak, vibration or heat mark without dismantling energized equipment. The checks should follow the machine documentation. Related component guides are included to help organize the request, not to recommend replacing several items without a diagnosis.
A symptom involving Level sensor should be described alongside the programme stage and the first alarm shown. An interrupted supply, a restricted mechanical movement or an incorrect signal can produce similar symptoms. Record whether the fault is constant, intermittent or linked to heat, load or moisture. Keep earlier and later alarms separate. This sequence helps a qualified technician decide which checks are appropriate instead of treating the last displayed message as a complete diagnosis.
Before a Level sensor is replaced, the machine must be placed in the condition required by its maintenance procedure. Electrical power, stored pressure, temperature and moving assemblies need appropriate control by qualified personnel. The replacement specification should be agreed before removal, including the mounting and connection arrangement. After fitting, the relevant functional and acceptance checks belong in the maintenance record. Replacing a component without checking the reason for its failure can leave the original problem in place.
This edition covers enquiries from Belarus. The geographical directory contains 314 populated-place records and 165 administrative-area records. Capital city: Minsk. These records describe the directory, not the number of service offices, and do not confirm a technician at that location. Your actual city, service options and delivery arrangements are checked individually for each enquiry before assistance or shipment is agreed.
A sensor produces a signal that travels through wiring and is interpreted by the controller before a value appears. The display therefore does not independently verify the sensing element and connection. Compare the real process condition, documented signal and expected input. Resistance, switching contacts and analog outputs require different interpretation. Do not infer a signal standard or pin arrangement from the body shape alone. The original code helps establish which comparison method is relevant to that sensor.
Compare method, range, output and mounting against the code, including any pressure or sensing line. Pressure-operated switch.
The specified range and installed sensing position both matter. Depending on the principle, compare the pocket, target gap, flow direction or contact surface. Use the original code, dimensions and connection with the candidate's technical information. Record slow response separately from a value that never changes. A method appropriate for one sensor family does not automatically apply to another. The operating principle determines which reference and installation details are meaningful when assessing the measured behaviour.
Record actual level and controller signal together; a missing indication may involve the sensing connection as well as the sensor. Float level switch.
Record the program, process condition and duration of the unusual reading, including whether it changes or stays fixed. A warning disappearing after restart is not proof of permanent correction. Keep observations such as deposits, moisture, cable movement and connection condition separate from measured findings. State the reference and time of comparison. Without input type and operating range, one number rarely supports a complete diagnosis, so include the context needed to interpret it correctly.
Sensing method, range, output, mounting position Pressure-operated switch.
Send the full model and serial number, the existing Level sensor code and a readable machine plate photograph. Include the component label, connector and mounting arrangement if these can be photographed safely. The same brand can use different revisions across machine families and production periods. If the old part was already replaced, include both codes and explain which one was originally fitted. This information supports an identification check; the brand and a general description alone are not enough. Float level switch.
A photograph is a useful starting point for Level sensor, but it cannot verify every specification. Hidden dimensions, internal construction, signal type or material can differ between similar-looking items. Compare the label and documented requirements as well as the visible shape. The gallery may contain a reference photograph or a clearly marked technical illustration. Neither image should be read as proof of the current stock, original manufacturer or compatibility with every Tolon, Tolkar or Kromlüks machine. Pressure-operated switch.
Describe the first symptom, programme stage and alarm in their original order. Explain whether the issue appears during starting, filling, heating, rotation, discharge or another identifiable operation. For Level sensor, add recent maintenance, operating conditions and any verified measurements with their units. Avoid turning an untested suspicion into a confirmed diagnosis. Qualified personnel can then compare the evidence with the machine documentation and decide whether the requested component or a connected assembly needs further investigation. Float level switch.
Availability and price are checked against the identified Level sensor, required quantity and agreed specification. For an enquiry from Belarus, provide the actual city and delivery destination so that feasible shipment options can be discussed. The presence of a product page does not establish stock or an agreed dispatch date. Any offered alternative needs a separate compatibility check. The quotation should identify what is included and which delivery conditions still require confirmation before an order is accepted. Pressure-operated switch.
After fitting Level sensor, the machine-specific maintenance procedure determines the functional checks and conditions for returning the equipment to use. Qualified personnel should confirm the relevant connections, mounting and operating response, then record the result alongside the original symptom. An alarm disappearing once is not proof that an intermittent cause has been resolved. Where the fault involved a supply, leak, abnormal load or mechanical restriction, that condition also needs to be addressed before the replacement is considered successful. Float level switch.
Tunçkol Makina is an independent private service and spare parts business. This Level sensor page provides identification guidance for enquiries involving Tolon, Tolkar and Kromlüks equipment; it does not declare an authorized relationship with those brands. Our confirmed contact address is in Ankara, Turkey. A country or city edition helps organize an enquiry, while local attendance, remote assistance and shipment feasibility must be confirmed separately for the actual request and location. Pressure-operated switch.